Atomiser Quality Control: Spray Pattern, Dosage per Stroke and Leak Testing

Checks on the incoming pump lot, on the filling line and on the finished product: the spray pattern test on paper, dosage by weighing ten strokes and its distribution, priming count, inverted and temperature-cycle leak tests, crimp and screw checks, and records.

Esans.com.tr Academy ·✍️ Esans Academy Technical Team ·~8 min read·Updated: 21.10.2026
01

Atomiser Quality Control: The First Part the Customer Touches

When a customer uses a perfume for the first time, they experience the pump before the scent: is the stroke stiff, is the spray fine, did the first stroke come out empty, is the underside of the cap oily? The pump is the most touched and most complained-about part of the product. The incoming goods inspection you do for fragrance oil you must also do for the pump.

Pump inspection rests on four measurements: spray pattern, dosage (output per stroke), leak-tightness and mechanical function (actuation force, priming, tube). All four can be done in the workshop without instruments; paper, a scale and time are enough.

Inspection is done at three points: when the pump batch arrives (incoming goods), on the filling line (in-process) and on the finished product (final inspection). This article covers all three.

When a pump batch arrives, at least 10 pieces are sampled, 20 for large batches. From the beginning, middle and end of the batch; not from a single box.
02

Spray Pattern Test

Spray pattern is the shape and fineness of the mist the pump produces. What is wanted in perfume is a wide, evenly distributed fine mist; what is unwanted is a narrow jet, a spray with droplets, or a pattern that veers to one side.

TestHowAcceptReject
Paper patternSingle stroke from a filled bottle onto white paper at 15 cm; paper held uprightCircular mist mark of even density, 6–10 cm in diameterJet, droplets, half-moon, concentration at the edge
Visual in lightDark background, side lighting; watch the strokeConical, even, rapidly dispersing mistVisible droplets, double jet, dripping after the stroke
Nozzle dripping5 seconds after the stroke, touch the nozzle to white paperDry or a very small markDistinct drop; nozzle wet after every stroke
Repeatability5 consecutive strokes with the same pumpFive identical patternsPattern changes from stroke to stroke

Test the pattern with the product itself, not with water. Perfume's viscosity and surface tension differ from water's; a pump that sprays well with water may drip with alcohol-based perfume, and vice versa. For oil-based products a spray pump is mostly unsuitable; these products call for a roll-on or a dropper.

03

Dosage and Leak-Tightness Test: Step by Step

The dosage test verifies the microlitre value on the pump's label; the leak-tightness test shows that the product will not cause trouble on the shelf or in a handbag.

  1. Record the priming count

    Spray a filled bottle with a new pump for the first time; count how many empty strokes it takes until the first full spray. 2–5 is normal; above 8 is a tube or pump problem.

  2. Weigh the dosage

    Weigh the bottle on a 0.01 g scale, make 10 full strokes, weigh again. Difference ÷ 10 = grams per stroke. Divide by the product density (~0.85–0.90 g/ml for alcohol-based perfume) → microlitres. Repeat on 10 pumps.

  3. Look at the dosage spread

    The average should be within ±10% of the label value; individual pumps should not exceed ±15%. If one pump deviates a lot, test 10 more pumps from the batch.

  4. Inverted leak-tightness

    Leave 5 filled, capped bottles upside down on white paper for 48 hours. A mark on the paper, wetness around the neck or a film inside the cap is grounds for rejection.

  5. Temperature cycle

    Keep the same bottles at 40°C for 24 hours, then at room temperature for 24 hours; check leak-tightness and spray pattern again. This represents summer shipping.

  6. Actuation force

    Without an instrument, compare by hand: the approved reference pump and the new batch are sprayed side by side; marked stiffness or looseness is noted. A stiff pump means customer complaints, a loose pump means emptying in the handbag.

  7. Tube check

    Hold the bottle up to the light: the tube should end 2–3 mm short of the bottom, not bend, not rub against the wall. If the pump draws air when you tilt the bottle and spray, the tube is too short.

FIGURE 01Process Strip — Step by Step
🔹1. Record thepriming count…🔹2. Weigh thedosage Weigh the…✅3. Look at thedosage spread The…🔹4. Invertedleak-tightness…🔹5. Temperaturecycle Keep the…🔹6. Actuation forceWithout an…
The dosage test is also the basis for any "number of sprays" claim. With a 50 ml bottle and a measured 0.09 g/stroke (roughly 100 µl), the bottle gives not 500 strokes but 450–480 once the product left at the bottom is deducted. That is the figure that goes in the marketing copy.
04

Inspection on the Filling Line and on the Finished Product

Even if the incoming pump batch passes clean, problems can arise during filling: wrong crimping pressure, a pump seated crooked, a tube cut short, a dirty nozzle. Line inspection catches these.

Crimp check. At the start of every batch and every 100 bottles: try to turn and pull the crimped pump by hand; if it turns or moves, the crimp is insufficient. The lower edge of the crimp collar should sit at an even distance from the bottle neck; a collar that is high on one side and low on the other is a crooked crimp and will leak.

Screw check. For hand-tightened pumps torque is undefined; the practical measure is to tighten the pump "a quarter turn past where it stops". Overtightening crushes the gasket, undertightening leaks. At the end of filling, leave 5 random bottles upside down overnight.

Finished product final inspection. 3–5 bottles from each batch: priming, spray pattern, cap fit, traces of fragrance oil on the outer surface. These bottles can also be set aside as retained samples; when the pump inspection is done on these samples, it is written into the batch record.

When a complaint comes in ("the pump doesn't work", "it emptied in my bag"), the first thing to look at is the pump inspection record for that batch. Without a record, you cannot tell whether the complaint concerns a single bottle or the whole batch.

05

Frequently Asked Questions

The most common questions about atomiser quality control.

How many pumps should I test?
At least 10 in an incoming batch, 20 in a large batch; 1 in every 100 bottles on the filling line; 3–5 per batch on the finished product. If deviation is seen, the number is increased.
Can I measure dosage with water?
Do not. Water's density and surface tension are different; dosage and pattern change. Test with the real product or at least with a blank formula at the same alcohol level.
The pump comes out empty on the first stroke; will customers complain?
2–5 priming strokes is normal and occurs in luxury perfumes too. Adding a note to the product card, "spray a few times on first use", prevents complaints. Above 8 is a technical problem.
The spray pattern comes out like a jet; what could be the cause?
The nozzle (insert) is blocked or of the wrong type, the product viscosity is high, or the nozzle pattern does not suit the product. First clean the nozzle with alcohol; if it does not improve, ask for a different nozzle type.
There is slight wetness in the inverted test; is that a reject?
A visible mark on white paper or liquid collecting at the neck is grounds for rejection. A very small amount of moisture at the nozzle tip alone is product left from the last stroke; it should not occur on a bottle left standing unsprayed.
How do I set the pressure on the crimping machine?
Start from the setting the manufacturer gives for the FEA size; crimp a sample bottle, check that the collar sits evenly and the pump does not turn, then test 5 bottles upside down. Write the setting in the batch record.
The underside of the cap is oily; is the pump leaking?
Not always. Product that got onto the neck area during filling may not have been wiped off. Clean the bottle, cap it, leave it upside down for 48 hours; if it gets oily again, it is a pump or crimping problem.
How should I keep the pump inspection record?
One line in the batch record: pump supplier and lot, number tested, average dosage, priming, leak-tightness result, crimp setting, inspector. In a complaint this is the first line you look at.